Waldent Protaper Hand File 21mm – S2

1,095.00

Description

Waldent Protaper Hand Files are quality files which feature a better nickel titanium construction than ProTaper Universal Rotary Files – plus ISO-colored handles
Their variable taper and advanced flute design offer efficiency to achieve consistent shaping, even under calcified canals.

Out of stock

Description
Reviews (0)

Description

Waldent Protaper Hand Files are quality files which feature a better nickel titanium construction than ProTaper Universal Rotary Files – plus ISO-colored handles
Their variable taper and advanced flute design offer efficiency to achieve consistent shaping, even under calcified canals.

FEATURES

  • Easy

– Only one instrument sequence whatever the canal shape
– Colour-coded and easy to follow protocol
– Drying and obturation solutions specifically designed for Protaper® files, with the same colour-codes for instant identification

  • Fast

– Only 3 instruments needed for most cases
– High cutting power

  • Efficient

– Apical taper for good canal cleaning
– Fantastic debris removal due to the unique ‘Multiple Taper’ design of these instruments

PACKAGE CONTENTS

  • 6 Files (Sx,S1,S2,F1,F2,F3)

Features1) Cross – section

Triangular Cross-Section

Convex : S1, S2, SX, F1, F2

Concave : F3

2) High Flexibility

Triangular concave cross-section : Flexibility

3) Tip

Modified Non cutting tip – Prevent Transportation

Acts as a Guide

4) Rust Free

Corrosion Resistant

5) Disinfection

Autoclavable

Key Specifications:

Shaping Files

Variable Increasing Taper(Eiffel Tower shape)

S1 – 18

S2 – 20

Sx – 19

Finishing Files

F1, F2, F3 Shape the Apical part of the canal

Variable Decreasing Taper

F1 20-7%

F2 25-8%

F3 30-9%

Packaging:
  • Pack of 6 Files
Direction to Use:

Treatment Sequence

SCOUTING THE CANAL :

  • Stainless steel K-File 010
  • Stainless steelC+ File08,10,15
  • ProFinder Files 10,13,17
  • Pathfiles

 

The lubricating action of Glyde helps the instruments to slide in the canal and Establish working length

Don’t use Sx deep in the canal
If needed, use SX with a brushing motion to relocate the orifice of the canal and create a straight line access(don’t use Sx deep in the canal)

Use S1 with a brushing motion
and enlarge the canal, no deeper than the level of the penetration of the scouting file(to make sure that the tip of S1is never blocked)Using Pathfile, go to working length that you established earlier

After going to length with a stainless steel file size 15, use :
S1 to working lengthwith a brushing motion.Using Pathfile this step is skipped

When S1 reaches working length, use :
S2 to working lengthwith a brushing motion

When S2 reaches working length, use :
F1 to working length.CAUTION !NEVER USE A BRUSHING ACTION WITH THE FINISHING FILES !!!When a finishing file reaches the working length,It is immediately withdrawn.

NEVER USE A BRUSHING ACTION WITH THE FINISHING FILES !!!
Gauge the diameter of the foramen with stainless steel files and if the foramen is larger than 20, use F2, F3 to working length, according to the real apical diameter.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.